This chapter provides guidelines on door height and width based on the function of the structure.
Front door landing requirements.
There shall be a floor or landing on each side of each exterior door.
Minimum number at least 60 of public entrances must be accessible in new construction in addition to entrances directly serving tenancies parking facilities pedestrian tunnels and elevated walkways.
Where a door opens over a landing the landing shall be at least as wide as the door and at least 5 feet long.
Title 24 part 2 section 2 3303 i 2 exception 1.
Any ramp system that is intended for public use must comply with the americans with disabilities act ada.
Step from the threshold down to the landing on both sides of the door.
The width of each landing shall not be less than the door served.
Every landing shall have a minimum dimension of 36 inches measured in the direction of travel.
There shall be a floor or landing on each side of a door.
Here is how the florida building code describes landings at doors.
Title 24 part 2 section 2 3303 i 1 and i 2 exception.
I am going to be rebuilding my front steps out of wood soon.
I have five steps to get into the house.
There are many regulations and calculations that go into designing an ada ramp but the ramp landing size is commonly miscalculated because the door size door swing and ramp approach are often not considered.
Where the door opens into the stairway of a smokeproof enclosure the landing need not have a length of 5 feet.
This guide explains scoping and technical requirements for accessible entrances doors and gates in the ada standards.
Such floor or landing shall be at the same elevation on each side of the door.
Doors other than the required egress door shall be provided with landings or floors not more than 7 3 4 inches 196 mm below the top of the threshold.
Exterior landings shall be permitted to have a slope not to exceed unit vertical in 12 units horizontal 2 percent.
Landing requirements for egress exterior doors.
Code requirements for exterior doors are covered in chapter 10 of the ibc.
Where a stairway of two or fewer risers is located on the exterior side of a door other than the required exit.
A top landing is not required where a stairway of not more than two risers is located on the exterior side of the door provided that the door does not swing over the stairway.
After all these wise choices are made double check them against the minimum code requirements.
In our opinion a landing on both sides of a door is recommended for practical reasons and such a landing is indeed required by some codes.
Stairway landing requirements for front door access richard from maine writes.